STE2 rev.2 / WLD2 / SD devices

 VersionRelease dateFile sizeDownload

STE2 rev.2 / WLD2 / SD devices 1.5.9

1.5.908/02/2024 - 10:11894.02 KB

Fix: PHY default settings

 VersionRelease dateFile sizeDownload

STE2 rev.2 / WLD2 / SD devices 1.5.6

1.5.609/21/2023 - 14:33894.94 KB

Fix: DNS resolving

 VersionRelease dateFile sizeDownload

STE2 rev.2 / WLD2 / SD devices 1.5.5

1.5.508/28/2023 - 09:04894.92 KB

Fix: SNMP

 VersionRelease dateFile sizeDownload

STE2 rev.2 / WLD2 / SD devices 1.5.4

1.5.406/26/2023 - 13:50894.77 KB
  • Add: 60 sec timeout for DHCP, then set the address from the configuration
  • Mod: Change the default IP address from 192.168.1.90 to 192.168.10.20, see STE2 R2 manual
  • Mod: Changing the Default button in UDP setup to 60 seconds as the manual says, it was 30
  • Mod: Saving of the uni sensor unit in the configuration
  • Fix: Disable file upload in demomode
  • Fix: DI reading period
  • Fix: uptime in snmp
  • Fix: web refresh after fw upload.
  • Fix: files with OID description
 VersionRelease dateFile sizeDownload

STE2 rev.2 / WLD2 / SD devices 1.5.2

1.5.205/24/2023 - 10:02894.67 KB
  • Fix SNMP traps for STE2 PLUS
  • Fix: DHCP
  • Fix Text Demo mode in Demo mode in page header
  • Fix: network stability
 VersionRelease dateFile sizeDownload

STE2 rev.2 / WLD2 / SD devices 1.4.9

1.4.901/11/2023 - 09:30787.2 KB

Fix: Generating self-signed certificates

 VersionRelease dateFile sizeDownload

STE2 rev.2 / WLD2 / SD devices 1.4.8

1.4.808/31/2022 - 08:48787.19 KB

Fix: Saving calibration values

 VersionRelease dateFile sizeDownload

STE2 rev.2 / WLD2 / SD devices 1.4.7

1.4.707/29/2022 - 09:49787.14 KB

Fix: HTTPS certificate

 VersionRelease dateFile sizeDownload

STE2 rev.2 / WLD2 / SD devices 1.4.6

1.4.606/22/2022 - 11:16790.98 KB
  • Fix: TLS connection for Office 365
 VersionRelease dateFile sizeDownload

STE2 rev.2 / WLD2 / SD devices 1.4.5 (1236)

1.4.5 (1236)05/18/2022 - 10:36790.92 KB
  • Fixed non-functional autopush
  • Fixed non-defaulting device in situations where access to configuration was unavailable
  • Added support for wifi detection with WPA2/WPA3, WPA2 enterprise, WPA3 security
  • added locking of configuration when pushing
  • added 30sec pause for push after sensor discovery
  • Fixed opening virtual output connections.
  • modification of UDP setup in STE2
  • added debug sensors for wld, sensors behave like normal sensor, i.e. logging, alarm, etc. are applied to them.
  • modified ADC calculation to take into account the reference set on the calibration.xml page
  • added debug.xml page where debug mode can be enabled. After enabling and restarting the box, it creates diagnostic sensors on the WLD that show resistance
  • The eth driver sets the pins and thus the mod during initialization. The mod is periodically checked and if it is changed (e.g. by static), it will reset the box after 10 sec.
  • Fixed behavior during sensor wipe and after boot
  • Invalid value is now -999.9 regardless of exponent
  • Fixed reading of hwg UNI configuration
  • Translated with www.DeepL.com/Translator (free version)
  • Fix Hwg-push after controlling the output from the sensor desk
  • Fix: TLS adding SNI extension for multicertificate
 VersionRelease dateFile sizeDownload

STE2 rev.2 / WLD2 / SD devices 1.4.3

1.4.308/24/2021 - 13:24781.44 KB
  • Add: inputs counters for SD-2xIn
  • Fix: solved the freezing of the network, which caused the clock to overflow and at the same time unavailable wifi
  • Mod: extension of wifi link WDT for 5 min-refactoring code
  • Mod: stopping / starting dhcp when disconnecting / connecting to wifi
  • Fix: device crash that occurred during high traffic over SSL
  • Mod: increased XML version for HWg-PUSH
 VersionRelease dateFile sizeDownload

STE2 rev.2 / WLD2 / SD devices 1.4.2

1.4.206/10/2021 - 07:47782.22 KB

Fix: periodic restart
Fix: Push - instead of micro push, a normal push was sent
Add: websocket support for output control

 VersionRelease dateFile sizeDownload

STE2 rev.2 / WLD2 / SD devices 1.4.1

1.4.106/01/2021 - 10:49782.13 KB

Fix: water detection in SD-Water and WLD2

 VersionRelease dateFile sizeDownload

STE2 rev.2 / WLD2 / SD devices 1.4.0

1.4.005/28/2021 - 09:50782.03 KB
  • Fix: text in SNMP OID sysDescription changed from Device Name to Device type + FW version
  • Fix: HWg-Push in SD-2xOUT devices
 VersionRelease dateFile sizeDownload

STE2 rev.2 / WLD2 / SD devices 1.3.12

1.3.1203/23/2021 - 10:44762.48 KB
  • Add: The ability to disable WLD entries and disable them from the system
  • Mod: correction of default values at input
  • Mod: edit text on the portal.xml website
  • Add: log protection with invalid time
  • Fix: manual push at zero push period. There is a loop
 VersionRelease dateFile sizeDownload

STE2 rev.2 / WLD2 / SD devices 1.3.11

1.3.1101/12/2021 - 09:08741.63 KB
  • Mod: New logo for STE2 r2
  • Add: Support for low power sensors
 VersionRelease dateFile sizeDownload

STE2 rev.2 / WLD2 / SD devices 1.3.10

1.3.1012/16/2020 - 11:05739.83 KB
  • Add: support for up to 5 sensors for STE2 r2
  • Add: 1-Wire UNI sensor support
  • Add: sensor status flag in push log
  • Fix: of possible memory leak when generating the certificate
  • Fix: character care using escape sequences in values.xml
  • Fix: edit site, freeze fields when DHCP is on / off
  • Mod: increase the length of the username and password fields in smtp
  • Mod: xml parser. Newly, the removal of the Esc sequence is performed directly during the parsing process and not during processing
  • Mod: disable display of hidden wifi networks
  • Mod: autopush method
  • Mod: outputs are assigned to the AutoPush. A local change in the value of the output caused a AutoPush
  • Mod: a change in the output value from the sensdesk triggered a AutoPush to let the portal know about the changes
 VersionRelease dateFile sizeDownload

STE2 rev.2 / WLD2 / SD devices 1.3.9

1.3.909/29/2020 - 16:45738.5 KB
  • Fix: increased the length of the username and password field for smtp to 32 characters
  • Fix: SNMP, now responds to the interaction from which the packet came
  • Fix: wifi reconfiguration when changing certain wifi parameters
  • Fix: display of sensor type on portal.xml page
  • Mod: end of time parsing from the sensdesk via info message
 VersionRelease dateFile sizeDownload

STE2 rev.2 / WLD2 / SD devices 1.3.8

1.3.809/11/2020 - 14:57740.73 KB
  • Mod: new default push period 300sec
  • Mod: redesign of a uniform push time, from which the individual log entries are offset
  • Fix: getting the sensor driver when sending data to the portal, so it does not interfere with the operation of the sensor
  • Add: SD-4-20mA product support
  • Mod: setting the datalog send flag when it is not empty after pushy
  • Mod: disable datalog deletion after check pushy
  • Mod: setting the logging flag for pushy only when retransmitting == 0, and pushy not triggered by a check period or event of sending the rest of the datalog
  • Mod: correction of sending inaccurate values Value, min, max, hyst, ap_delta at exponent less than -1
  • Mod: change of work with sensor units (UNI sensor units did not promote the system)
  • Fix: freezing portal datalog, reaching beyond its poartition
  • Add: import and export from SPI flash portal datalog
  • Add: web push indicator
  • Mod: change the way the status.xml download is suspended on the web
  • Add: Calibration for SD-4-20ma (exponent and linear interpolation in 8 point)
  • Mod: Tuning of SD4-20ma sensor values
  • Fix: Autopush - When the sensdesk was unavailable, it pushed (and therefore logged)
  • Fix: Inserting time from sensor board into retransmit, when push error was wrong device time
 VersionRelease dateFile sizeDownload

STE2 rev.2 / WLD2 / SD devices 1.3.7

1.3.708/12/2020 - 09:55739.98 KB
  • Canceled Autopush setting for digital inputs on Portal page. Now depends on the "Alarm Alert" option the Inputs page
 VersionRelease dateFile sizeDownload

STE2 rev.2 / WLD2 / SD devices 1.3.6

1.3.607/30/2020 - 07:36740.06 KB
  • MOD: Extend the field by e-mail to 64 characters
  • Fix: LED operation inside 1-Wire connectors
  • Fix: Change the time synchronization period on the Time page
  • Minor modifications and improvements to the WWW
 VersionRelease dateFile sizeDownload

STE2 rev.2 / WLD2 / SD devices 1.3.5

1.3.507/15/2020 - 13:13739.56 KB
  • Add: long pushlog (256kB)
  • Mod: design HTML pages
  • Fix: Sending values with correct exponent in HWg-Push
  • Add: Outputs to the values.xml
 VersionRelease dateFile sizeDownload

STE2 rev.2 / WLD2 / SD devices 1.3.3

1.3.305/26/2020 - 10:07736.91 KB
  • Fix: Flood detection on SD-WLD
  • Fix: Undefined state between Normal and Flooded on SD-WLD and WLD2
  • Add: Support for counters on inputs (SD-2xIN)
  • Add: SD-4-20mA support
  • Add: Calibration table for SD-4-20mA
  • Add: Internal calibration page SD-WLD
  • Add: Support for FRAM memory (counters support)
  • Add: Listing of wifi modem status to setup.xml page
  • Mod: HTML, JavaScripts and CSS on Alarms.xml page
  • Fix. Improved link on portal.xml page, so from dynamics it refers to address according to field server address and ip port
 VersionRelease dateFile sizeDownload

STE2 rev.2 / WLD2 / SD devices 1.3.1

1.3.101/14/2020 - 08:40698.05 KB
  • Fix: Sending Push message when Alarm Start or Alarm End
 VersionRelease dateFile sizeDownload

STE2 rev.2 / WLD2 / SD devices 1.3.0 (1)

1.3.0 (1)12/10/2019 - 13:35697.77 KB

First public release

 VersionRelease dateFile sizeDownload

STE2 rev.2 / WLD2 / SD devices 1.2.1

1.2.108/09/2019 - 13:18701.77 KB

Fix: Support 1-Wire UNI for SD Devices

 VersionRelease dateFile sizeDownload

STE2 rev.2 / WLD2 / SD devices 1.2.0

1.2.008/02/2019 - 13:00701.5 KB
  • Mod: Change XML version for HWg-Push protocol from 4.02 to 4.03. The change is backward compatible => Push Protocol Variable Extension: [r/w] Portal/Team, Portal/TeamPass and [ro] Agent/ConfigSaveTime

Subscribe for
software releases

CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.

HWG newsletter