Product map - Detector
Primary tabs
The detectors you connect to a DI input (green connector), providing a value of 0/1. A typical example is a smoke detector with a relay output or a door opening detector (door open/closed). The monitoring device (SensDesk) can monitor the switching to the alarm value and send an e-mail or SMS alarm. You can connect detectors with relay output from any manufacturer to the HW group's monitoring device's DI input.
AirFlow sensor 5101 |
Door contact MK4 |
Gas Leak Detector |
Motion PIR Detector |
Optical Smoke Detector FDR26 |
Power Detector |
PowerEgg2 |
Sensor WLD Relay 1W-UNI |
Vibration detector SS14 |
Vibration detector SS14-v2 |
||
---|---|---|---|---|---|---|---|---|---|---|---|
Measurement | Measurement |
Flow Range: 0–1 switch Accuracy: 1 Resolution: 1.00 Technology: Semiconductor |
Switch Range: 0–1 switch Resolution: 0.00 |
Range: 0–1 switch Resolution: 0.00 |
Motion |
Smoke Range: 0–1 switch Accuracy: 1 Resolution: 1.00 Technology: Semiconductor |
Voltage | Voltage |
Water detection Technology: Resistor |
Vibration | Vibration |
Number of values provided | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | |
Inputs |
Counters: NO
|
Inputs type: Wet Contact Counters: NO
Inputs type: Dry Contact Counters: NO
|
Inputs type: Water Leak Detection zone Quantity: 1 Counters: NO
|
||||||||
Outputs |
Output type: Relays standard Load voltage: 230V / 3000mA |
Output type: Relays standard Quantity: 1 Load voltage: 50V / 500mA |
Output type: Relays standard Quantity: 1 Load voltage: 230V / 5000mA |
Output type: Open colectors Quantity: 1 Load voltage: 50V / 50mA |
Output type: Relays standard Quantity: 1 Load voltage: 50V / 500mA |
Output type: Open colectors Quantity: 1 Load voltage: 50V / 130mA |
Output type: Relays 110/230V Load voltage: 230V / 8000mA Output type: Relays standard Quantity: 1 Load voltage: 120V AC/60V DC / 1000mA |
Output type: Relays standard Load voltage: 50V / 1000mA |
Output type: Open colectors Load voltage: 120V AC/60V DC / 40mA |
Output type: Open colectors Load voltage: 30V DC / 100mA |
|
Cable length | 2 meter | 2 meter | None | None | None | None | None | 3 meter | None | None | |
Galvanic isolation | 1 | 1 | 1 | 0 | 1 | 1 | 1 | 0 | 1 | 1 | |
Units Converter | NO | NO | NO | NO | NO | NO | NO | YES | NO | NO | |
Calibrated Points | None | None | None | None | None | None | None | None | None | None | |
Power and dimensions | Power supply |
Power supply: 24V / 40mA Connector: Wire |
Power supply: 12V / 100mA Connector: Terminal Block |
Power supply: 12V / 35mA Connector: Terminal Block |
Power supply: 12V / 55mA Connector: Terminal Block |
Power supply: 230V / 3mA |
Power supply: 230V / 13mA Connector: IEC-320 C14 |
Power supply: 9-15V / 20mA Connector: Jack (barrel, inner 2,1 mm outer 5,5 mm) Power supply: 9-15V / 20mA Connector: Terminal Block Power supply: 5V / 40mA Connector: RJ-11 (from 1-Wire) |
Power supply: 12V / 18mA Connector: Terminal Block |
Power supply: 12V / 20mA Connector: Terminal Block |
|
Operating environment | -10°C ÷ 50°C / 0%RH ÷ 90%RH | -20°C ÷ 80°C / 0%RH ÷ 100%RH | -10°C ÷ 40°C / 25%RH ÷ 75%RH | -10°C ÷ 40°C / 20%RH ÷ 80%RH | 0°C ÷ 70°C / 0%RH ÷ 95%RH | -30°C ÷ 60°C / 0%RH ÷ 100%RH | -20°C ÷ 80°C / 0%RH ÷ 80%RH | -30°C ÷ 85°C / 0%RH ÷ 100%RH | -20°C ÷ 50°C / 0%RH ÷ 100%RH | -20°C ÷ 50°C / 0%RH ÷ 95%RH | |
Storage environment | -30°C ÷ 60°C / 5%RH ÷ 95%RH | -30°C ÷ 60°C / 5%RH ÷ 95%RH | -20°C ÷ 50°C / 5%RH ÷ 95%RH | -30°C ÷ 60°C / 5%RH ÷ 95%RH | -30°C ÷ 60°C / 5%RH ÷ 95%RH | -30°C ÷ 60°C / 5%RH ÷ 95%RH | -30°C ÷ 60°C / 5%RH ÷ 95%RH | -30°C ÷ 60°C / 5%RH ÷ 95%RH | -30°C ÷ 60°C / 5%RH ÷ 95%RH | -20°C ÷ 50°C / 0%RH ÷ 95%RH | |
Depth | 10mm | 39mm | 53mm | 50mm | 41mm | 34mm | 21mm | 21mm | |||
Dimensions | 24mm / 141mm / / 157g | 12mm / 51mm / 10mm / 50g | 100mm / 74mm / 39mm / 112g | 61mm / 110mm / 53mm / 77g | 100mm / 45mm / / 185g | 60mm / 60mm / 50mm / 80g | 58mm / 124mm / 41mm / 146g | 79mm / 68mm / 34mm / 122g | 37mm / 78mm / 21mm / 33g | ||
Type | Environment | Industrial, IT | Industrial, SoHo, IT | Industrial, SoHo, IT | SoHo, IT | SoHo, IT | Industrial, SoHo, IT | Industrial, SoHo, IT | Industrial, IT | Industrial, SoHo | Industrial, SoHo |
Installation | Rack, Wall | Table, Wall | Wall | Wall | Rack, Table, Wall | Table, Wall | Wall | ||||
IP Rating | IP67 | IP40 | IP33 | IP33 | IP40 | IP23 | IP33 | IP23 | IP30 | ||
Connectors | Terminal Block | Terminal Block | Terminal Block | Terminal Block | Terminal Block | Terminal Block | Terminal Block | RJ11, Terminal Block | Terminal Block | Terminal Block | |
Design | Rod, Room | Dry contact | Dry contact | Mural | Mural | Mural | Mural | Mural | Mural |