Standalone Monitoring products can be used independently (portal is not required). Devices are sending emails, can be connected via SNMP to NMS (Network Monitoring System). Standalone products are multi-purpose, device configuration is more complex and connecting the product to the portal is only one of the functions. Using a central portal does not limit the sending of alarms from the devices and other standalone functions.


Perseus Monitoring 140

Perseus Monitoring 145

Perseus Monitoring 150

Perseus Monitoring 155

Protocols

Protocols

IPv6 YES YES YES YES
SNMP SNMP v1 + SNMP v3 SNMP v1 + SNMP v3 SNMP v1 + SNMP v3 SNMP v1 + SNMP v3
SNMP Trap
SNMP trap: 
1
SNMP trap: 
1
SNMP trap: 
1
SNMP trap: 
1
COAP NO NO NO NO
DHCP YES YES YES YES
HTTP YES YES YES YES
HTTPS YES YES YES YES
XML YES YES YES YES
SMTP
SMTP: 
1
SMTP: 
1
SMTP: 
1
SMTP: 
1
SMTP TLS YES YES YES YES
HWg-Push (SensDesk) YES YES YES YES
NB-Push NO NO NO NO
HWg-DCD NO NO NO NO
Net-GSM (SMS GW) YES YES YES YES
MQTT YES YES YES YES
Modbus/TCP YES YES YES YES
Syslog NO NO NO NO

Meters API

Meters API

Meters limit 100 100 100 100
Meters API: 1-Wire YES YES YES YES
Meters API: RS-485/HWg NO NO NO NO
Meters API: Modbus/RTU YES YES YES YES
Meters API: Modbus/TCP YES YES YES YES
Meters API: HWg XML YES YES YES YES
Meters API: SNMP YES YES YES YES
Meters API: MQTT YES YES YES YES
Meters API: M-Bus NO NO NO NO

Sensors

Sensors

Variables limit 1000 1000 1000 1000
1-Wire values* 100 100 100 100
RS-485 values* 100 100 100 100
Number of 1-Wire ports 4 4 8 8
Number of RS-485 ports 1 1 1 1
Inputs
Inputs type: Dry Contact
Quantity: 4
Counters: YES

Inputs type: Water Leak Detection zone
Quantity: 1
Counters: NO
Inputs type: Dry Contact
Quantity: 4
Counters: YES

Inputs type: Water Leak Detection zone
Quantity: 1
Counters: NO
Inputs type: Dry Contact
Quantity: 16
Counters: YES

Inputs type: Water Leak Detection zone
Quantity: 1
Counters: NO
Inputs type: Dry Contact
Quantity: 16
Counters: YES

Inputs type: Water Leak Detection zone
Quantity: 1
Counters: NO
Outputs
Output type: Relays standard
Quantity: 2
Load voltage: 120V AC/60V DC / 1000mA
Output type: Relays standard
Quantity: 2
Load voltage: 120V AC/60V DC / 1000mA
Output type: Relays standard
Quantity: 4
Load voltage: 120V AC/60V DC / 1000mA
Output type: Relays standard
Quantity: 4
Load voltage: 120V AC/60V DC / 1000mA
Box2Box
Box2Box type: XML
Quantity: 1000
Box2Box type: XML
Quantity: 1000
Box2Box type: XML
Quantity: 1000
Box2Box type: XML
Quantity: 1000

Alarms

Alarms

Trap destinations 100 100 100 100
SMS dest. (via SMS GW) 100 100 100 100
Alarm reminder YES YES YES YES
Periodical status YES YES YES YES

Power and dimensions

Power and dimensions

Power supply
Power supply: 9-30V / 500mA
Connector: Jack (barrel, inner 2,1 mm outer 5,5 mm)

Power supply: 9-30V / 500mA
Connector: Terminal Block
Power supply: 9-30V / 500mA
Connector: Jack (barrel, inner 2,1 mm outer 5,5 mm)

Power supply: 9-30V / 500mA
Connector: Terminal Block
Power supply: 9-30V / 500mA
Connector: Jack (barrel, inner 2,1 mm outer 5,5 mm)

Power supply: 9-30V / 500mA
Connector: Terminal Block

Power supply: 48V / 250mA
Connector: Terminal Block

Power supply: PoE / 250mA
Connector: RJ-45
Power supply: 9-30V / 500mA
Connector: Jack (barrel, inner 2,1 mm outer 5,5 mm)

Power supply: 9-30V / 500mA
Connector: Terminal Block

Power supply: 48V / 250mA
Connector: Terminal Block

Power supply: PoE / 250mA
Connector: RJ-45
PoE/48V NO NO YES YES
Operating environment -30°C ÷ 85°C / 5%RH ÷ 95%RH -30°C ÷ 60°C / 5%RH ÷ 95%RH -30°C ÷ 85°C / 5%RH ÷ 95%RH -30°C ÷ 65°C / 5%RH ÷ 95%RH
Storage environment -30°C ÷ 65°C / 5%RH ÷ 95%RH -30°C ÷ 60°C / 5%RH ÷ 95%RH -30°C ÷ 65°C / 5%RH ÷ 95%RH -30°C ÷ 65°C / 5%RH ÷ 95%RH
Depth 35mm 35mm 38mm 38mm
Dimensions 140mm / 111mm / 35mm / 550g 140mm / 111mm / 35mm / 550g 300mm / 145mm / 38mm / 1120g 300mm / 145mm / 38mm / 1120g

Interface

Interface

Ethernet 10/100Mbit 10/100Mbit 10/100Mbit 10/100Mbit
WiFi NO NO NO NO
Mobile networks NO LTE NO LTE
RS-232 NO NO NO NO
RS-485 YES YES YES YES

Type

Type

Environment Industrial, SoHo, IT Industrial, SoHo, IT Industrial, SoHo, IT Industrial, SoHo, IT
Installation Rack, Table Rack, Table Rack, Table Rack, Table
IP Rating IP40 IP40 IP40 IP40
* Sensor limit per port depends on hardware interface and components used, see manual for more information.