Product map - Standalone Monitoring
![](https://www.hw-group.com/files/styles/hwg_distrib_term_thumbnail/public/taxonomy/1/standalonemonitoring.png)
Standalone Monitoring products can be used independently (portal is not required). Devices are sending emails, can be connected via SNMP to NMS (Network Monitoring System). Standalone products are multi-purpose, device configuration is more complex and connecting the product to the portal is only one of the functions. Using a central portal does not limit the sending of alarms from the devices and other standalone functions.
![]() STE2 LITE |
![]() STE2 PLUS |
![]() STE2 PLUS SMS-GW |
![]() STE2 R2 |
||
---|---|---|---|---|---|
Protocols | IPv6 | NO | YES | YES | NO |
SNMP | SNMP v1 | SNMP v1 + SNMP v3 | SNMP v1 + SNMP v3 | SNMP v1 | |
SNMP Trap |
SNMP trap: 0 |
SNMP trap: 1 |
SNMP trap: 1 |
SNMP trap: 0 |
|
DHCP | YES | YES | YES | YES | |
HTTP | YES | YES | YES | YES | |
HTTPS | YES | YES | YES | YES | |
XML | YES | YES | YES | YES | |
SMTP |
SMTP: 1 |
SMTP: 1 |
SMTP: 1 |
SMTP: 1 |
|
SMTP TLS | YES | YES | YES | YES | |
HWg-Push (SensDesk) | YES | YES | YES | YES | |
Net-GSM (SMS GW) | YES | YES | YES | NO | |
MQTT | NO | NO | NO | NO | |
Modbus/TCP | NO | NO | NO | NO | |
Syslog | NO | YES | YES | NO | |
Sensors | 1-Wire values* | 4 | 15 | 15 | 5 |
Number of 1-Wire ports | 1 | 2 | 2 | 2 | |
Inputs |
Quantity: 0 |
Inputs type: Dry Contact Quantity: 2 Counters: NO
|
Inputs type: Dry Contact Quantity: 2 Counters: NO
|
Quantity: 2 |
|
Outputs |
Output type: Not supported |
Output type: Not supported |
Output type: Not supported |
||
Box2Box |
Box2Box type: XML Quantity: 8 |
Box2Box type: XML Quantity: 8 |
|||
Alarms | Trap destinations | 0 | 5 | 5 | 0 |
SMS dest. (via SMS GW) | 5 | 5 | 5 | 5 | |
Alarm reminder | NO | YES | YES | ||
Periodical status | NO | YES | YES | ||
Power and dimensions | Power supply |
Power supply: 5V / 250mA Connector: Jack (barrel, inner 1,35 mm outer 3,5 mm) |
Power supply: 5V / 300mA Connector: Jack (barrel, inner 1,35 mm outer 3,5 mm) Power supply: PoE / 60mA Connector: RJ-45 (from Ethernet) |
Power supply: 5V / 300mA Connector: Jack (barrel, inner 1,35 mm outer 3,5 mm) Power supply: PoE / 60mA Connector: RJ-45 (from Ethernet) Power supply: 9-30V / 250mA Connector: Jack (barrel, inner 2,1 mm outer 5,5 mm) Power supply: 9-30V / 250mA Connector: Terminal Block |
Power supply: 5V / 300mA Connector: Jack (barrel, inner 1,35 mm outer 3,5 mm) Power supply: PoE / 60mA Connector: RJ-45 (from Ethernet) |
PoE/48V | NO | YES | YES | YES | |
Operating environment | -10°C ÷ 60°C / 0%RH ÷ 95%RH | -10°C ÷ 60°C / 0%RH ÷ 95%RH | -10°C ÷ 60°C / 0%RH ÷ 95%RH | -10°C ÷ 60°C / 0%RH ÷ 95%RH | |
Storage environment | -30°C ÷ 60°C / 0%RH ÷ 95%RH | -30°C ÷ 60°C / 0%RH ÷ 95%RH | -30°C ÷ 60°C / 0%RH ÷ 95%RH | -30°C ÷ 60°C / 0%RH ÷ 95%RH | |
Depth | 29mm | 33mm | 33mm | 33mm | |
Dimensions | 63mm / 67mm / 29mm / 64g | 98mm / 68mm / 33mm / 91g | 98mm / 68mm / 33mm / 91g | 98mm / 68mm / 33mm / 91g | |
Interface | Logger size | Not supported | Not supported | Not supported | |
Ethernet | 10/100Mbit | 10/100Mbit | 10/100Mbit | NO | |
WiFi | IEEE 802.11bgn | IEEE 802.11bgn | IEEE 802.11bgn | IEEE 802.11bgn | |
Mobile networks | NO | NO | NO | NO | |
RS-232 | NO | NO | NO | NO | |
RS-485 | NO | NO | NO | NO | |
Type | Environment | SoHo | SoHo, IT | SoHo, IT | |
Installation | Table | DIN, Table | DIN, Table | DIN, Table, Wall | |
IP Rating | IP40 | IP40 | IP40 | IP40 |
* Sensor limit per port depends on hardware interface and components used, see manual for more information.