Product map - Standalone Monitoring
Standalone Monitoring products can be used independently (portal is not required). Devices are sending emails, can be connected via SNMP to NMS (Network Monitoring System). Standalone products are multi-purpose, device configuration is more complex and connecting the product to the portal is only one of the functions. Using a central portal does not limit the sending of alarms from the devices and other standalone functions.
STE2 LITE |
STE2 PLUS |
STE2 PLUS SMS-GW |
STE2 R2 |
||
---|---|---|---|---|---|
Protocols | IPv6 | NO | YES | YES | NO |
SNMP | SNMP v1 | SNMP v1 + SNMP v3 | SNMP v1 + SNMP v3 | SNMP v1 | |
SNMP Trap |
SNMP trap: 0 |
SNMP trap: 1 |
SNMP trap: 1 |
SNMP trap: 0 |
|
DHCP | YES | YES | YES | YES | |
HTTP | YES | YES | YES | YES | |
HTTPS | YES | YES | YES | YES | |
XML | YES | YES | YES | YES | |
SMTP |
SMTP: 1 |
SMTP: 1 |
SMTP: 1 |
SMTP: 1 |
|
SMTP TLS | YES | YES | YES | YES | |
HWg-Push (SensDesk) | YES | YES | YES | YES | |
Net-GSM (SMS GW) | YES | YES | YES | NO | |
MQTT | NO | NO | NO | NO | |
Modbus/TCP | NO | NO | NO | NO | |
Syslog | NO | YES | YES | NO | |
Sensors | 1-Wire values* | 4 | 15 | 15 | 5 |
Number of 1-Wire ports | 1 | 2 | 2 | 2 | |
Inputs |
Quantity: 0 |
Inputs type: Dry Contact Quantity: 2 Counters: NO
|
Inputs type: Dry Contact Quantity: 2 Counters: NO
|
Quantity: 2 |
|
Outputs |
Output type: Not supported |
Output type: Not supported |
Output type: Not supported |
||
Box2Box |
Box2Box type: XML Quantity: 8 |
Box2Box type: XML Quantity: 8 |
|||
Alarms | Trap destinations | 0 | 5 | 5 | 0 |
SMS dest. (via SMS GW) | 5 | 5 | 5 | 5 | |
Alarm reminder | NO | YES | YES | ||
Periodical status | NO | YES | YES | ||
Power and dimensions | Power supply |
Power supply: 5V / 250mA Connector: Jack (barrel, inner 1,35 mm outer 3,5 mm) |
Power supply: 5V / 300mA Connector: Jack (barrel, inner 1,35 mm outer 3,5 mm) Power supply: PoE / 60mA Connector: RJ-45 (from Ethernet) |
Power supply: 5V / 300mA Connector: Jack (barrel, inner 1,35 mm outer 3,5 mm) Power supply: PoE / 60mA Connector: RJ-45 (from Ethernet) Power supply: 9-30V / 250mA Connector: Jack (barrel, inner 2,1 mm outer 5,5 mm) Power supply: 9-30V / 250mA Connector: Terminal Block |
Power supply: 5V / 300mA Connector: Jack (barrel, inner 1,35 mm outer 3,5 mm) Power supply: PoE / 60mA Connector: RJ-45 (from Ethernet) |
PoE/48V | NO | YES | YES | YES | |
Operating environment | -10°C ÷ 60°C / 0%RH ÷ 95%RH | -10°C ÷ 60°C / 0%RH ÷ 95%RH | -10°C ÷ 60°C / 0%RH ÷ 95%RH | -10°C ÷ 60°C / 0%RH ÷ 95%RH | |
Storage environment | -30°C ÷ 60°C / 0%RH ÷ 95%RH | -30°C ÷ 60°C / 0%RH ÷ 95%RH | -30°C ÷ 60°C / 0%RH ÷ 95%RH | -30°C ÷ 60°C / 0%RH ÷ 95%RH | |
Depth | 29mm | 33mm | 33mm | 33mm | |
Dimensions | 63mm / 67mm / 29mm / 64g | 98mm / 68mm / 33mm / 91g | 98mm / 68mm / 33mm / 91g | 98mm / 68mm / 33mm / 91g | |
Interface | Logger size | Not supported | Not supported | Not supported | |
Ethernet | 10/100Mbit | 10/100Mbit | 10/100Mbit | NO | |
WiFi | IEEE 802.11bgn | IEEE 802.11bgn | IEEE 802.11bgn | IEEE 802.11bgn | |
Mobile networks | NO | NO | NO | NO | |
RS-232 | NO | NO | NO | NO | |
RS-485 | NO | NO | NO | NO | |
Type | Environment | SoHo | SoHo, IT | SoHo, IT | |
Installation | Table | DIN, Table | DIN, Table | DIN, Table, Wall | |
IP Rating | IP40 | IP40 | IP40 | IP40 |
* Sensor limit per port depends on hardware interface and components used, see manual for more information.